Air Gap Flux
Quartzteq have developed tailor made solutions for identifying magnetic air gap flux through consistently monitoring the magnetic state of machines offering owners/operators up-to-date, reliable information with regards generator status.
A solution developed specifically for turbo-alternators
Identifies rotor winding shorts and earth faults
Simple and low cost flux probe set-up
Suitable for operation with LIFEVIEW PDA II, LIFEVIEW LIVE or LIFEVIEW MOBILE analysers
The Air Gap Flux Probe measures the air gap flux in the turbo-alternator, between the stator and the rotor with the flux probes installed in the slots of the stator. By measuring and analysing the air-gap flux we are able to determine a shorted turn in the rotor winding which indicates which turn is shorted. Other information, such as eccentricity can also be detected. These probes are compatible with the LIFEVIEW PDA II, LIFEVIEW LIVE and LIFEVIEW MOBILE analysers, offering either permanent or periodic monitoring, and are custom designed and fabricated for each application. One probe is usually installed per machine.